Products

Multi Gas Monitor SXi type Real Time

High-sensitivity multi-gas monitor that instantaneously measures in real time H2, CO2, C6H6, etc.,

  • Hydrogen Concentration Range : 0.1 to 100% can be measured without switching on.
  • Measurable Range of Hydrogen Concentration : 100ppm to 100%
  • Hydrogen Detection Response Time : 0.3 second or below (standard capillary 1m),
    Gas consumption 21cm3(STEP)/min
  • Mass Spectrometry Measurement : M/Z=1 ~ 100
  • Standard Gas Cylinder Installed Inside(All components excluding moisture present in a typical air)
  • Interactive Format by Japanese Language
  • Able to preset measurement menu
  • Text File Conversion Utility available at option
  • Anti-vibration trucks available at option
  • Main Application

Diffusion of hydrogen gas, immediate measurement of gas concentration change at time of leakage, monitoring hydrogen during the R&Ds of a fuel cell and/or secondary battery, concentration measurement of combustion gases, monitoring the concentration of volatile solvent, catalyst reaction observation, monitoring ambient gases and soil contamination examination

  • Specifications
  • Standard capillary : length : 1m (inside diameter 0.25mm)
  • Electric power supply: AC100V(50/60Hz)
  • Communication : RS232C (Cable is provided with the equipment)
  • Maximum rated current : at the time of measurement : about 3A(300W) ;at start-up about 4A(400W)
  • Permissible ambient temperature : 0 ~ 40 DC
  • Size : W:485 X D: 185 X H:490mm(H=565 handle being included)
  • Weight : about 30 Kgs (it varies depending on system configuration)

The equipment can only be operated in Japan, and its export is prohibited. Specification is subject to change for improvements without notice.

Multi Gas Monitor SXi-FCV Type

Real time multi gas monitor equipped with dehumidifier installed inside can instantaneously measure in highly humid environment.

  • Hydrogen Detection Response Time : 1.5second or below (it varies depending on capillary length)
  • Mass Spectrometry Measurement : M/Z=1 ~ 100 (300 measurable at maximum)
  • Standard Gas Cylinder Installed Inside: can be easily operated using interactive format
  • Interactive Format by Japanese Language
  • Dehumidifier can be installed at option
  • Text File Conversion Utility available at option
  • Main Application

Monitoring exhaust-gas from fuel cell car(FCV), for Fuel Cell development & Monitoring Hydrogen Gas, for Secondary Battery Development, Measuring combustion gas, observing catalyst reaction, Monitoring ambient gases and Monitoring soil contamination, etc.

  • Specifications
  • Standard capillary : length : 1m (inside diameter 0.25mm)
  • Electric power supply: AC100V(50/60Hz)
  • Communication : RS232C (Cable is provided with the equipment)
  • Maximum rated current : at the time of measurement : about 3A(300W) ;at start-up about 4A(400W)
  • Permissible ambient temperature : 0 ~ 40 DC
  • Size : W:584 X D: 228 X H:660mm(H=680 handle being included)
  • Weight : about 38 Kgs (it varies depending on system configuration)

The equipment can only be operated in Japan, and its export is prohibited. Specification is subject to change for improvements without notice.

Multi Gas Monitor SXw Type

High-sensitivity multi-gas monitor that in real time responds instantaneously to hydrogen, cycloaromatic compounds , odor components of aromatics and toxic gases even in dilute condition.

  • Hydrogen Detection Response Time : 0.3second or below (it varies depending on capillary length)
  • Measurable range of hydrogen density : 100ppm to 100%
  • Mass Spectrometry Measurement : M/Z=1 ~ 100 (300 measurable at maximum)
  • Standard Gas Cylinder Installed Inside: can be easily operated using interactive format
  • Interactive Format by Japanese Language
  • Dehumidifier can be installed at option
  • Text File Conversion Utility available at option
  • Main Application

Monitoring exhaust-gas from fuel cell car(FCV), for Fuel Cell development & Monitoring Hydrogen Gas, for Secondary Battery Development, Measuring combustion gas, observing catalyst reaction, Monitoring ambient gases and Monitoring soil contamination, etc.

  • Specifications
  • Standard capillary : length : 1m (inside diameter 0.25mm)
  • Electric power supply: AC100V(50/60Hz)
  • Communication : RS232C (Cable is provided with the equipment)
  • Maximum rated current : at the time of measurement : about 3A(300W) ;at start-up about 4A(400W)
  • Permissible ambient temperature : 0 ~ 40 DC
  • Size : W:584 X D: 228 X H:660mm(H=680 handle being included)
  • Weight : about 38 Kgs (it varies depending on system configuration)

The equipment can only be operated in Japan, and its export is prohibited. Specification is subject to change for improvements without notice.